9751EN Control Panel


9751EN Control Panel:

The Scantronic 9751EN is a fully programmable, 8 zone security alarm panel designed to conform to PD6662:2004 Grade 2 system requirements.

The panel includes an integral dialler modem that can communicate any alarm activation or service information to an Alarm Receiving Centre.

Expandable up to 24 zones using the 9954 wired or RFX08/RFX16 868MHz narrow-band wire-free expanders, the 9751EN provides flexibility whatever your security requirements. The wire-free expanders eliminate the need for complex and unsightly wiring further minimising disruption to your décor during installation.

The 9751EN is ideally suited to home, small commercial and industrial security applications combining maximum flexibility with ease of use to provide optimum security when and where you need it. Simple A, B, C and D setting buttons allow you to split the system into four individually-controlled sub-systems enabling you to set the whole, or just parts of the alarm protection.

Up to 4 attractive remote keypads can be added to any system. The 9751EN-41 comes with the 9941 keypad (as pictured) and uses 4 or 6-digit PIN codes to control system operation. The 9751EN-43 comes with the 9943 keypad, which provides the added feature of allowing users to set and unset the system using a personal encrypted key-ring tag.

As well as an integral modem for alarm and service information, the 9751EN has full remote upload/download capability allowing your installer to programe and perform routine service and diagnostic tests without having to visit the premises.

 

 

 

The Scantronic 9751EN is a fully programmable, 8 zone security alarm panel designed to conform to PD6662:2004 Grade 2 system requirements.

The panel includes an integral dialler modem that can communicate any alarm activation or service information to an Alarm Receiving Centre.

Expandable up to 24 zones using the 9954 wired or RFX08/RFX16 868MHz narrow-band wire-free expanders, the 9751EN provides flexibility whatever your security requirements. The wire-free expanders eliminate the need for complex and unsightly wiring further minimising disruption to your décor during installation.

The 9751EN is ideally suited to home, small commercial and industrial security applications combining maximum flexibility with ease of use to provide optimum security when and where you need it. Simple A, B, C and D setting buttons allow you to split the system into four individually-controlled sub-systems enabling you to set the whole, or just parts of the alarm protection.

Up to 4 attractive remote keypads can be added to any system. The 9751EN-41 comes with the 9941 keypad (as pictured) and uses 4 or 6-digit PIN codes to control system operation. The 9751EN-43 comes with the 9943 keypad, which provides the added feature of allowing users to set and unset the system using a personal encrypted key-ring tag.

As well as an integral modem for alarm and service information, the 9751EN has full remote upload/download capability allowing your installer to programme and perform routine service and diagnostic tests without having to visit the premises.

Specifications

 

General

 
Product name 9751
Security Grade BS4737
Sales number 09751UK-50
Product Description 24 Zone Panel plus 99xx keypad
   

Capacities

 
Max zones 24
Zones - on board 8 FSL or 8CC (with common tamper)
Zones - on expander(s) 16
Standard wired outputs - on board 3
Communicator outputs: 8
Outputs on expander module(s) None
Setting Levels: 1 Full + 2 Part (one partition)
Partitions: None
Log capacity (events): 250
No. Keypads 4
Internal Clock ±10 minutes over one year (depending on the accuracy of the mains supply frequency).
Downloader Yes
Remote Servicing Yes
   

Security

 
Access code  4 digits
Number of user codes 16 plus installer plus duress
Code blocking Blocked for 90s after 13 incorrect characters in series.
Proximity tag differs 4,294,967,296
   

Physical

 

End Station

 
End Station dimensions: 245(W), 235(H), 90(D) mm
End Station weight (w/o battery): 2.45 kg
Case material Steel
   

Keypad

 
Keypad name 9941/9943
   

Environmental

 
Environmental Grade Class II
Operating temperature -10° to +55°C
Humidity 96% RH
   

Radio

 
Expander/Built-in: Expander (see RFX08 or RFX16)
   

PSTN Communications

 
Built in Communicator Yes
Plug on communicator No
Plug-by communicator Provides 8 programmable outputs for plug-by module.
Protocols: Fast Format, SIA, SIA II, SIA III, Contact ID
Speech Dialler No
ATS rating 2
Line sharing This product can share a PSTN line with other telephony or fax equipment.
REN 1
   

Power Supply

 
EN50131-6 Type A
Mains power supply 230VAC +10%/-15%, 1A max, 50Hz ±5%
End station psu 13.8VDC, 1.0A
End station consumption 115mA quiescent, 150mA active
Communicator consumption n/a
Standby Battery 12V rechargeable lead-acid, gel-type battery. Note that a 17Ah battery cannot fit inside the case.
Standby time:  Depends on battery
Max recharge time: Depends on battery
12V Aux supply (inc LS) 500mA, 12VDC minimum, 13.8VDC maximum, ripple ±2% maximum.
14V4 supply None
12V Keypad bus None
Monitoring includes Mains fail, battery low voltage, battery failure.
   

Data Connections

None
   

Wired Outputs

 
Bell trigger None
Strobe trigger None
O/P 1 Open-collector transistor outputs, 500mA, 12VDC, negative applied.
O/P 2 Open-collector transistor outputs, 500mA, 12VDC, negative applied.
O/P 3 Open-collector transistor outputs, 500mA, 12VDC, negative applied.
O/P 4 None
O/P 5-8 None
LS (loudspeaker) Supports two parallel-connected, externally mounted loudspeakers for internal sounder or EE tones: minimum speaker impedance 16Ω.
Communication outputs 12V logic outputs, negative applied in alarm (positive removed), 50mA maximum.
ST (Siren test) None
   

Wired Inputs

 
TR Tamper return for Bell
Tellback/Remote reset** +12V applied to operate reset.
Line Fault input** +12V applied to indicate line failure.
Aux Tmp None
   

Fuses

 
Mains T-250mA 250V.
Other 12V Aux = 1A Fast
  Battery = 2A Fast

Coming soon!

Join Our Email List:

Newsletter, Promotions, and more.
Please wait
efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot спам-efosbot