9751EN Control Panel
The Scantronic 9751EN is a fully programmable, 8 zone security alarm panel designed to conform to PD6662:2004 Grade 2 system requirements.
The panel includes an integral dialler modem that can communicate any alarm activation or service information to an Alarm Receiving Centre.
Expandable up to 24 zones using the 9954 wired or RFX08/RFX16 868MHz narrow-band wire-free expanders, the 9751EN provides flexibility whatever your security requirements. The wire-free expanders eliminate the need for complex and unsightly wiring further minimising disruption to your décor during installation.
The 9751EN is ideally suited to home, small commercial and industrial security applications combining maximum flexibility with ease of use to provide optimum security when and where you need it. Simple A, B, C and D setting buttons allow you to split the system into four individually-controlled sub-systems enabling you to set the whole, or just parts of the alarm protection.
Up to 4 attractive remote keypads can be added to any system. The 9751EN-41 comes with the 9941 keypad (as pictured) and uses 4 or 6-digit PIN codes to control system operation. The 9751EN-43 comes with the 9943 keypad, which provides the added feature of allowing users to set and unset the system using a personal encrypted key-ring tag.
As well as an integral modem for alarm and service information, the 9751EN has full remote upload/download capability allowing your installer to programme and perform routine service and diagnostic tests without having to visit the premises.
Specifications
General |
|
Product name | 9751 |
Security Grade | BS4737 |
Sales number | 09751UK-50 |
Product Description | 24 Zone Panel plus 99xx keypad |
Capacities |
|
Max zones | 24 |
Zones - on board | 8 FSL or 8CC (with common tamper) |
Zones - on expander(s) | 16 |
Standard wired outputs - on board | 3 |
Communicator outputs: | 8 |
Outputs on expander module(s) | None |
Setting Levels: | 1 Full + 2 Part (one partition) |
Partitions: | None |
Log capacity (events): | 250 |
No. Keypads | 4 |
Internal Clock | ±10 minutes over one year (depending on the accuracy of the mains supply frequency). |
Downloader | Yes |
Remote Servicing | Yes |
Security |
|
Access code | 4 digits |
Number of user codes | 16 plus installer plus duress |
Code blocking | Blocked for 90s after 13 incorrect characters in series. |
Proximity tag differs | 4,294,967,296 |
Physical |
|
End Station |
|
End Station dimensions: | 245(W), 235(H), 90(D) mm |
End Station weight (w/o battery): | 2.45 kg |
Case material | Steel |
Keypad |
|
Keypad name | 9941/9943 |
Environmental |
|
Environmental Grade | Class II |
Operating temperature | -10° to +55°C |
Humidity | 96% RH |
Radio |
|
Expander/Built-in: | Expander (see RFX08 or RFX16) |
PSTN Communications |
|
Built in Communicator | Yes |
Plug on communicator | No |
Plug-by communicator | Provides 8 programmable outputs for plug-by module. |
Protocols: | Fast Format, SIA, SIA II, SIA III, Contact ID |
Speech Dialler | No |
ATS rating | 2 |
Line sharing | This product can share a PSTN line with other telephony or fax equipment. |
REN | 1 |
Power Supply |
|
EN50131-6 Type | A |
Mains power supply | 230VAC +10%/-15%, 1A max, 50Hz ±5% |
End station psu | 13.8VDC, 1.0A |
End station consumption | 115mA quiescent, 150mA active |
Communicator consumption | n/a |
Standby Battery | 12V rechargeable lead-acid, gel-type battery. Note that a 17Ah battery cannot fit inside the case. |
Standby time: | Depends on battery |
Max recharge time: | Depends on battery |
12V Aux supply (inc LS) | 500mA, 12VDC minimum, 13.8VDC maximum, ripple ±2% maximum. |
14V4 supply | None |
12V Keypad bus | None |
Monitoring includes | Mains fail, battery low voltage, battery failure. |
Data Connections |
None |
Wired Outputs |
|
Bell trigger | None |
Strobe trigger | None |
O/P 1 | Open-collector transistor outputs, 500mA, 12VDC, negative applied. |
O/P 2 | Open-collector transistor outputs, 500mA, 12VDC, negative applied. |
O/P 3 | Open-collector transistor outputs, 500mA, 12VDC, negative applied. |
O/P 4 | None |
O/P 5-8 | None |
LS (loudspeaker) | Supports two parallel-connected, externally mounted loudspeakers for internal sounder or EE tones: minimum speaker impedance 16Ω. |
Communication outputs | 12V logic outputs, negative applied in alarm (positive removed), 50mA maximum. |
ST (Siren test) | None |
Wired Inputs |
|
TR | Tamper return for Bell |
Tellback/Remote reset** | +12V applied to operate reset. |
Line Fault input** | +12V applied to indicate line failure. |
Aux Tmp | None |
Fuses |
|
Mains | T-250mA 250V. |
Other | 12V Aux = 1A Fast |
Battery = 2A Fast |